Modular data center solutions

We design & manufacture mobile HPC infrastructure.

Deploy high-density compute capacity in 12 to 16 weeks instead of years. From HPC containers to transformers, BESS, generators, cooling and GPU clusters: a complete modular data center, ready to operate anywhere in the world.

Talk to an engineer
Datacube HPC container
12–16
weeks, order to operation
1.5 MW
per modular ISO container
  • Full stack: compute, power, cooling & monitoring
  • Optional BESS and diesel generator integration
  • Turn-key: from MV connection to GPU-ready racks
  • Ideal for AI clusters, HPC, rendering & simulation
  • Designed in alignment with EN 50600
  • Suited for NVIDIA & AMD
A fully modular data center, delivered turn-key

Every part built off-site, pre-tested, plug-and-play.

This drastically reduces engineering time, civil works and deployment risk.

HPC containers
Rear Door Heat Exchanger (RDHx)
Direct Liquid Cooled (DLC)
Immersion cooled
Suited for NVIDIA & AMD
Power modules
LV switchgear
PDU's
Busbars
Cooling modules
Closed-loop dry coolers
Pump modules
Heat-reuse hot-water loop
Energy modules
Battery Energy Storage Systems (BESS)
Diesel generator back-up
MV infrastructure
MV switchgear
Transformers
Compute
GPU clusters (NVIDIA & AMD)
Pre-configured racks

One HPC container. Three cooling technologies.

Full HPC solution →

Power and cooling infrastructure

The modules around the compute container: heat rejection, medium-voltage power and on-site generation, all containerised and pre-tested.

Infrastructure →
Other specifications
A+B power feed
Integrated LV panel
Integrated PLC
Monitored cooling loop
High efficiency dry cooler
Optional hot-water loop reuse
Customer customisations by request
Monitor and control
Beckhoff PLC
Modbus, SNMP & REST API
Power metering on main busbar, rack & outlet
Cooling loop telemetry (flow, pressure & temperature)
Generator / BESS integration
Cloud dashboard for remote operations: our CubeApp (CubeBridge on the edge, CubeTwin in the cloud)
Modular data center interior
Standards
EN 50600
CE
CSC / UL
The Datacubes ecosystem

From energy source to useful heat.

Power in, compute out, heat reused. Each step is a containerised module we design and manufacture ourselves.

Grid stabilisation

Absorb overproduction from renewable sources.

Energy parks

Convert energy at wind or solar farms that would otherwise be lost.

Remote locations

Immediate returns from energy at sites far from demand.

Heat reuse

Waste heat for district heating and industrial processes.

Ready to deploy your modular data center?

Tell us your power capacity, compute type and location. We send a full concept design with options.

Request a quote